System Administration Commands                                       cfgadm(8)



NAME
       cfgadm - configuration administration

SYNOPSIS
       /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_options]
            -c function ap_id...


       /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_options]
            -x hardware_function ap_id...


       /usr/sbin/cfgadm [-v] [-a] [-s listing_options]
            [-o hardware_options] [-l [ap_id | ap_type]]


       /usr/sbin/cfgadm [-v] [-o hardware_options] -t ap_id...


       /usr/sbin/cfgadm [-v] [-o hardware_options] -h
            [ap_id | ap_type]

DESCRIPTION
       The  cfgadm command provides configuration administration operations on
       dynamically reconfigurable hardware resources. These operations include
       displaying  status, (-l), initiating testing, (-t), invoking configura‐
       tion state changes, (-c), invoking hardware specific  functions,  (-x),
       and obtaining configuration administration help messages (-h). Configu‐
       ration administration is performed  at  attachment  points,  which  are
       places  where system software supports dynamic reconfiguration of hard‐
       ware resources during continued operation of Solaris.


       Configuration  administration  makes  a  distinction  between  hardware
       resources  that  are  physically  present  in  the machine and hardware
       resources that are configured and visible to  Solaris.  The  nature  of
       configuration  administration  functions are hardware specific, and are
       performed by calling hardware specific libraries.


       Configuration administration operates on an attachment point.  Hardware
       resources  located  at  attachment  points can or can not be physically
       replaceable during system operation, but are dynamically reconfigurable
       by way of the configuration administration interfaces.


       An  attachment  point  defines  two unique elements, which are distinct
       from the hardware resources that exist beyond the attachment point. The
       two  elements  of an attachment point are a receptacle and an occupant.
       Physical insertion or removal of hardware resources occurs  at  attach‐
       ment  points and results in a receptacle gaining or losing an occupant.
       Configuration  administration  supports  the  physical  insertion   and
       removal  operations as well as other configuration administration func‐
       tions at an attachment point.


       Attachment points have associated state and condition information.  The
       configuration administration interfaces provide control for transition‐
       ing attachment point states. A receptacle can exist  in  one  of  three
       states:  empty,  disconnected or connected, while an occupant can exist
       in one of two states: configured or unconfigured.


       A receptacle can provide the empty state, which is the normal state  of
       a  receptacle  when the attachment point has no occupants. A receptacle
       can also provide the disconnected state if it  has  the  capability  of
       isolating its occupants from normal system access. Typically this state
       is used for various hardware specific testing  prior  to  bringing  the
       occupant's  resources into full use by the system, or as a step in pre‐
       paring an occupant for physical removal or reconfiguration. A  recepta‐
       cle  in the disconnected state isolates its occupant from the system as
       much as its hardware allows, but can provide  access  for  testing  and
       setup. A receptacle must provide the connected state, which allows nor‐
       mal access to hardware resources contained on any occupants.  The  con‐
       nected state is the normal state of a receptacle that contains an occu‐
       pant and that is not currently undergoing configuration  administration
       operations.


       The  hardware  resources  contained  on an occupant in the unconfigured
       state are not represented by normal Solaris  data  structures  and  are
       thus  not available for use by Solaris. Operations allowed on an uncon‐
       figured occupant are limited  to  configuration  administration  opera‐
       tions.  The  hardware  resources of an occupant in the configured state
       are represented by normal Solaris data structures and thus some or  all
       of  those  hardware  resources  can be in use by Solaris. All occupants
       provide both the configured and unconfigured states,


       An attachment point can be in one  of  five  conditions:  unknown,  ok,
       failing,  failed, or unusable. An attachment point can enter the system
       in any condition depending upon results  of  power-on  tests  and  non-
       volatile record keeping.


       An  attachment point with an occupant in the configured state is in one
       of four conditions: unknown, ok, failing, or failed. If  the  condition
       is not failing or failed an attachment point can change to failing dur‐
       ing the course of operation if a hardware dependent  recoverable  error
       threshold  is  exceeded.  If  the condition is not failed an attachment
       point can change to failed during operation as a result of an  unrecov‐
       erable error.


       An  attachment  point with an occupant in the unconfigured state can be
       in any of the defined conditions. The condition of an attachment  point
       with  an  unconfigured  occupant  can  decay from ok to unknown after a
       machine dependent time threshold. Initiating a  test  function  changes
       the  attachment point's condition to ok, failing or failed depending on
       the outcome of the test. An attachment point that does  not  provide  a
       test  function can leave the attachment point in the unknown condition.
       If a test is interrupted, the attachment point's condition can  be  set
       to  the  previous  condition, unknown or failed. An attachment point in
       the unknown, ok, failing, or failed conditions can be re-tested.


       An attachment point can exist in the unusable condition for  a  variety
       of  reasons, such as inadequate power or cooling for the receptacle, an
       occupant that is unidentifiable, unsupported,  incorrectly  configured,
       etc. An attachment point in the unusable condition can never be used by
       the system. It typically remains in this condition until  the  physical
       cause is remedied.


       An attachment point also maintains busy information that indicates when
       a state change is in progress or the condition is being reevaluated.


       Attachment points are referred to using hardware  specific  identifiers
       (ap_ids)  that  are  related to the type and location of the attachment
       points in the system device hierarchy. An ap_id can not  be  ambiguous,
       it must identify a single attachment point. Two types of ap_id specifi‐
       cations are supported: physical and logical. A physical ap_id  contains
       a  fully specified pathname, while a logical ap_id contains a shorthand
       notation that identifies an attachment point in  a  more  user-friendly
       way.


       For example, an attachment point representing a system's backplane slot
       number 7 could have  a  physical  ap_id  of  /devices/central/fhc/sysc‐
       trl:slot7  while the logical ap_id could be system:slot7. Another exam‐
       ple, the third receptacle on the second PCI I/O bus on a  system  could
       have a logical ap_id of pci2:plug3.


       Attachment points may also be created dynamically. A dynamic attachment
       point is named relative to a base attachment point which is present  in
       the system. ap_ids for dynamic attachment points consist of a base com‐
       ponent followed by two colons (::) and a dynamic  component.  The  base
       component  is the base attachment point ap_id. The dynamic component is
       hardware specific and generated by the corresponding hardware  specific
       library.


       An  ap_type  is a partial form of a logical ap_id that can be ambiguous
       and not specify a particular attachment point. An  ap_type  is  a  sub‐
       string  of the portion of the logical ap_id up to but not including the
       colon (:) separator. For example, an ap_type  of  pci  would  show  all
       attachment points whose logical ap_ids begin with pci.


       The use of ap_types is discouraged. The new select sub-option to the -s
       option provides a more general and  flexible  mechanism  for  selecting
       attachment points. See OPTIONS.


       The  cfgadm  command  interacts primarily with hardware dependent func‐
       tions contained in hardware specific libraries and thus its behavior is
       hardware dependent.


       For  each configuration administration operation a service interruption
       can be required.  Should  the  completion  of  the  function  requested
       require  a  noticeable  service  interruption  to  interactive users, a
       prompt is output on the standard error output for confirmation  on  the
       standard  input  before  the  function  is started. Confirmation can be
       overridden using the -y or -n  options  to  always  answer  yes  or  no
       respectively.  Hardware  specific options, such as test level, are sup‐
       plied as sub-options using the -o option.


       Operations that change  the  state  of  the  system  configuration  are
       audited by the system log daemon syslogd(8).


       The  arguments  for  this command conform to the getopt(3C) and getsub‐
       opt(3C) syntax convention.

OPTIONS
       The following options are supported:

       -a

           Specifies that the -l option  must  also  list  dynamic  attachment
           points.


       -cfunction

           Performs  the  state change function on the attachment point speci‐
           fied by ap_id.

           Specify function as insert, remove, disconnect, connect,  configure
           or  unconfigure.  These  functions  cause  state transitions at the
           attachment point by calling hardware specific library routines  and
           are defined in the following list.


           insert         Performs operations that allows the user to manually
                          insert an occupant or to activate  a  hardware  sup‐
                          plied  mechanism  that  performs the physical inser‐
                          tion. insert can have hardware specific side effects
                          that temporarily suspend activity in portions of the
                          system. In such cases the hardware specific  library
                          generates  appropriate  warning messages and informs
                          the user of any special considerations or procedures
                          unique  to  that hardware. Various hardware specific
                          errors can cause this function to fail and  set  the
                          receptacle condition to unusable.


           remove         Performs  operations that allow the user to manually
                          remove an occupant or to activate  a  hardware  sup‐
                          plied  mechanism  to  perform  the physical removal.
                          remove can have hardware specific side effects  that
                          temporarily suspend activity in portions of the sys‐
                          tem. In such cases  the  hardware  specific  library
                          generates  appropriate  warning messages and informs
                          the user of any special considerations or procedures
                          unique  to  that hardware. Various hardware specific
                          errors can cause this function to fail and  set  the
                          receptacle condition to unusable.


           disconnect     Performs  hardware  specific  operations  to  put  a
                          receptacle in the disconnected state, which can pre‐
                          vent  an occupant from operating in a normal fashion
                          through the receptacle.


           connect        Performs hardware specific  operations  to  put  the
                          receptacle  in  the connected state, which allows an
                          occupant to operate in a normal fashion through  the
                          receptacle.


           configure      Performs  hardware specific operations that allow an
                          occupant's  hardware  resources  to  be  usable   by
                          Solaris.  Occupants  that are configured are part of
                          the  system  configuration  and  are  available  for
                          manipulation  by Solaris device manipulation mainte‐
                          nance  commands  (eg:  psradm(8),  mount(8),  ifcon‐
                          fig(8)).


           unconfigure    Performs hardware specific operations that logically
                          remove an occupant's  hardware  resources  from  the
                          system.  The  occupant  must currently be configured
                          and its hardware resources must not  be  in  use  by
                          Solaris.

           State  transition  functions  can  fail due to the condition of the
           attachment point or other hardware  dependent  considerations.  All
           state  change  functions  in  the  direction  of  adding resources,
           (insert, connect, and configure) are passed onto the hardware  spe‐
           cific  library  when  the  attachment point is in the ok or unknown
           condition. All other conditions require the use of the force option
           to  allow  these functions to be passed on to the hardware specific
           library. Attachment point condition does  not  prevent  a  hardware
           specific  library  being called for related to the removal (remove,
           disconnect, and unconfigure) of hardware resources from the system.
           Hardware  specific  libraries  can reject state change functions if
           the attachment point is in the unknown condition.

           The condition of an attachment point is not necessarily changed  by
           the  state  change  functions,  however  errors during state change
           operations can change the attachment point condition. An attempt to
           override  a condition and force a state change that would otherwise
           fail can be made by specifying the force option (-f). Hardware spe‐
           cific safety and integrity checks can prevent the force option from
           having any effect.


       -f

           Forces the specified action to occur. Typically, this is a hardware
           dependent  override  of  a  safety  feature. Forcing a state change
           operation can allow use of the hardware resources of occupant  that
           is  not  in  the ok or unknown conditions, at the discretion of any
           hardware dependent safety checks.


       -h [ap_id | ap_type ... ]

           Prints out the help message text. If ap_id or ap_type is specified,
           the  help  routine of the hardware specific library for the attach‐
           ment point indicated by the argument is called.


       -l [ap_id | ap_type ... ]

           Lists the state  and  condition  of  attachment  points  specified.
           Attachment points can be filtered by using the -s option and select
           sub-option. Invoking cfgadm without one of the  action  options  is
           equivalent  to  -l without an argument. The format of the list dis‐
           play is controlled by the -v and -s options. When the -a option  is
           specified attachment points are dynamically expanded.


       -n

           Suppress any interactive confirmation and assume that the answer is
           no. If neither -n or -y is specified, interactive  confirmation  is
           obtained  through the standard error output and the standard input.
           If either of these standard channels does not correspond to a  ter‐
           minal (as determined by isatty(3C)) then the -n option is assumed.


       -ohardware_options

           Supplies  hardware specific options to the main command option. The
           format and content of the  hardware  option  string  is  completely
           hardware  specific.  The option string hardware_options conforms to
           the getsubopt(3C) syntax convention.


       -slisting_options

           Supplies listing options to the list (-l) command.  listing_options
           conforms  to  the  getsubopt(3C) syntax convention. The sub-options
           are  used  to  specify  the  attachment  point  selection  criteria
           (select=select_string),    the    type    of    matching    desired
           (match=match_type), order of listing  (sort=field_spec),  the  data
           that  is displayed (cols=field_spec and cols2=field_spec), the col‐
           umn delimiter (delim=string) and whether to suppress  column  head‐
           ings (noheadings).

           When  the  select  sub-option  is specified, only attachment points
           which match the specified criteria will be listed. The select  sub-
           option has the following syntax:




             cfgadm -s select=attr1(value1):attr2(value2)...

           where  an  attr is one of ap_id, class or type. ap_id refers to the
           logical ap_id field, class refers to  attachment  point  class  and
           type  refers to the type field. value1, value2, etc. are the corre‐
           sponding values to be matched. The type of match can  be  specified
           by the match sub-option as follows:




             cfgadm -s match=match_type,select=attr1(value1)...


           where  match_type can be either exact or partial. The default value
           is exact.

           Arguments to the select sub-option can be quoted  to  protect  them
           from the shell.

           A  field_spec  is  one or more data-fields concatenated using colon
           (:), as in data-field:data-field:data-field. A data-field is one of
           ap_id,  physid,  r_state,  o_state,  condition,  type,  busy,  sta‐
           tus_time, status_time_p, class, and info. The ap_id field output is
           the  logical  name for the attachment point, while the physid field
           contains the physical name. The r_state field can be empty, discon‐
           nected  or connected. The o_state field can be configured or uncon‐
           figured. The busy field can be either y if the attachment point  is
           busy, or n if it is not. The type and info fields are hardware spe‐
           cific. The status_time field provides the time at which either  the
           r_state,  o_state,  or  condition  of  the  attachment  point  last
           changed. The status_time_p field is a parsable version of the  sta‐
           tus_time field. If an attachment point has an associated class, the
           class field lists the class name. If an attachment point  does  not
           have an associated class, the class field lists none.

           The  order of the fields in field_spec is significant: For the sort
           sub-option, the first field given is the primary sort key. For  the
           cols  and  cols2  sub-options,  the fields are printed in the order
           requested. The order of sorting on a data-field can be reversed  by
           placing a minus (−) before the data-field name within the field_sec
           for the sort sub-option. The default value for sort is  ap_id.  The
           defaults  values for cols and cols2 depend on whether the -v option
           is given: Without it cols  is  ap_id:r_state:o_state:condition  and
           cols2  is  not  set.  With -v  cols is ap_id:r_state:o_state:condi‐
           tion:info and cols2 is status_time:type:busy:physid:.  The  default
           value  for  delim  is  a  single space. The value of delim can be a
           string of arbitrary length. The delimiter cannot include comma  (,)
           character,  see getsubopt(3C). These listing options can be used to
           create parsable output. See NOTES.


       -t

           Performs a test of one or more attachment points. The test function
           is used to re-evaluate the condition of the attachment point. With‐
           out a test level specifier in hardware_options,  the  fastest  test
           that identifies hard faults is used.

           More  comprehensive  tests  are  hardware specific and are selected
           using the hardware_options.

           The results of the test is used to  update  the  condition  of  the
           specified  occupant to either ok if no faults are found, failing if
           recoverable faults are found or failed if any unrecoverable  faults
           are found.

           If  a  test is interrupted, the attachment point's condition can be
           restored to its previous value or set to unknown if no errors  were
           found or failing if only recoverable errors were found or to failed
           if any unrecoverable errors were found. The attachment point should
           only be set to ok upon normal completion of testing with no errors.


       -v

           Executes  in  verbose mode. For the -c, -t and -x options outputs a
           message giving the results of  each  attempted  operation.  Outputs
           detailed help information for the -h option. Outputs verbose infor‐
           mation for each attachment point for the -l option.


       -xhardware_function

           Performs hardware specific  functions.  Private  hardware  specific
           functions can change the state of a receptacle or occupant. Attach‐
           ment point conditions can change as the result  of  errors  encoun‐
           tered  during  private  hardware specific functions. The format and
           content of the hardware_function string is completely hardware spe‐
           cific.  The option string hardware_function conforms to the getsub‐
           opt(3C) syntax convention.


       -y

           Suppresses any interactive confirmation and assume that the  answer
           is yes.


USAGE
       The  required  privileges  to  use this command are hardware dependent.
       Typically, a default system configuration restricts all  but  the  list
       option to the superuser.

EXAMPLES
       Example 1 Listing Attachment Points in the Device Tree



       The  following  example  lists  all  attachment  points  except dynamic
       attachment points.




         example# cfgadm

           Ap_Id         Type        Receptacle      Occupant       Cond
         system:slot0    cpu/mem     connected       configured     ok
         system:slot1    sbus-upa    connected       configured     ok
         system:slot2    cpu/mem     connected       configured     ok
         system:slot3    unknown     connected       unconfigured   unknown
         system:slot4    dual-sbus   connected       configured     failing
         system:slot5    cpu/mem     connected       configured     ok
         system:slot6    unknown     disconnected    unconfigured   unusable
         system:slot7    unknown     empty           unconfigured   ok
         c0              scsi-bus    connected       configured     unknown
         c1              scsi-bus    connected       configured     unknown




       Example 2 Listing All Configurable Hardware Information



       The following example lists all current configurable hardware  informa‐
       tion, including those represented by dynamic attachment points:




         example# cfgadm -al

           Ap_Id            Type         Receptacle      Occupant        Cond
         system:slot0       cpu/mem      connected       configured      ok
         system:slot1       sbus-upa     connected       configured      ok
         system:slot2       cpu/mem      connected       configured      ok
         system:slot3       unknown      connected       unconfigured    unknown
         system:slot4       dual-sbus    connected       configured      failing
         system:slot5       cpu/mem      connected       configured      ok
         system:slot6       unknown      disconnected    unconfigured    unusable
         system:slot7       unknown      empty           unconfigured    ok
         c0                 scsi-bus     connected       configured      unknown
         c0::dsk/c0t14d0    disk         connected       configured      unknown
         c0::dsk/c0t11d0    disk         connected       configured      unknown
         c0::dsk/c0t8d0     disk         connected       configured      unknown
         c0::rmt/0          tape         connected       configured      unknown
         c1                 scsi-bus     connected       configured      unknown




       Example 3 Listing Selectively, Based on Attachment Point Attributes



       The  following  example  lists all attachment points whose class begins
       with scsi, ap_id begins with c and type field  begins  with  scsi.  The
       argument to the -s option is quoted to protect it from the shell.




         example# cfgadm -s "match=partial,select=class(scsi):ap_id(c):type(scsi)"

         Ap_Id         Type          Receptacle      Occupant           Cond
          c0          scsi-bus      connected       configured         unknown
          c1          scsi-bus      connected       configured         unknown




       Example  4 Listing Current Configurable Hardware Information in Verbose
       Mode



       The following example lists current configurable  hardware  information
       for ap-type  system in verbose mode:




         example# cfgadm -v -l system
         Ap_Id                      Receptacle Occupant   Condition Information
         When         Type      Busy     Phys_Id
         system:slot1               connected  configured ok
         Apr  4 23:50 sbus-upa  n        /devices/central/fhc/sysctrl:slot1
         system:slot3               connected  configured ok        non-detachable
         Apr 17 11:20 cpu/mem   n        /devices/central/fhc/sysctrl:slot3
         system:slot5               connected  configured ok
         Apr  4 23:50 cpu/mem   n        /devices/central/fhc/sysctrl:slot5
         system:slot7               connected  configured ok
         Apr  4 23:50 dual-sbus n        /devices/central/fhc/sysctrl:slot7





       The When column represents the status_time field.

       Example  5  Testing  Two Occupants Using the Hardware Specific Extended
       Test



       The following example tests two occupants using the  hardware  specific
       extended test:




         example# cfgadm -v -o extended -t system:slot3 system:slot5
         Testing attachment point system:slot3 ...  ok
         Testing attachment point system:slot5 ...  ok


       Example 6 Configuring an Occupant Using the Force Option



       The  following  example  configures an occupant in the failing state to
       the system using the force option:




         example# cfgadm -f -c configure system:slot3


       Example 7 Unconfiguring an Occupant From the System



       The following example unconfigures an occupant from the system:




         example# cfgadm -c unconfigure system:slot4


       Example 8 Configuring an Occupant at an Attachment Point



       The following example configures an occupant:




         example# cfgadm -c configure c0::dsk/c0t0d0


ENVIRONMENT VARIABLES
       See environ(7) for descriptions of the following environment  variables
       that  affect the execution of cfgadm: LC_TIME, LC_MESSAGES, NLSPATH and
       TZ.

       LC_MESSAGES    Determines how cfgadm displays column headings and error
                      messages.  Listing  output  data  is not affected by the
                      setting of this variable.


       LC_TIME        Determines how cfgadm  displays  human  readable  status
                      changed time (status_time).


       TZ             Specifies  the time zone used when converting the status
                      changed time. This applies to both  the  human  readable
                      (status_time) and parsable (status_time_p) formats.


EXIT STATUS
       The following exit values are returned:

       0    Successful completion.


       1    An error occurred.


       2    Configuration administration not supported on specified target.


       3    Usage error.


ATTRIBUTES
       See attributes(7) for descriptions of the following attributes:


       tab()  box; cw(2.75i) |cw(2.75i) lw(2.75i) |lw(2.75i) ATTRIBUTE TYPEAT‐
       TRIBUTE VALUE _ Availabilitysystem/dynamic-reconfiguration


SEE ALSO
       config_admin(3CFGADM),    getopt(3C),    getsubopt(3C),     isatty(3C),
       attributes(7),  environ(7),  cfgadm_fp(8), cfgadm_ib(8), cfgadm_pci(8),
       cfgadm_sata(8), cfgadm_sbd(8),  cfgadm_scsi(8),  cfgadm_usb(8),  ifcon‐
       fig(8), mount(8), prtdiag(8), psradm(8), syslogd(8)

DIAGNOSTICS
       Diagnostic  messages  appear  on  the standard error output. Other than
       options and usage errors, the following are  diagnostic  messages  pro‐
       duced by this utility:

         cfgadm: Configuration administration not supported on ap_id


         cfgadm: No library found for ap_id


         cfgadm: ap_id is ambiguous


         cfgadm: operation: Insufficient privileges


         cfgadm: Attachment point is busy, try again


         cfgadm: No attachment points with specified attributes found


         cfgadm: System is busy, try again


         cfgadm: operation: Operation requires a service interruption



         cfgadm: operation: Data error: error_text


         cfgadm: operation: Hardware specific failure: error_text



       See  config_admin(3CFGADM)  for additional details regarding error mes‐
       sages.

NOTES
       Hardware resources enter the unconfigured pool in a  hardware  specific
       manner.  This can occur at various times such as: system initialization
       or as a result of an unconfigure operation. An occupant that is in  the
       unconfigured  state  is  not available for use by the system until spe‐
       cific intervention occurs. This intervention can be  manifested  as  an
       operator  initiated command or it can be by way of an automatic config‐
       uring mechanism.


       The listing option of  the  cfgadm  command  can  be  used  to  provide
       parsable  input for another command, for example within a shell script.
       For parsable output, the -s option must be used to  select  the  fields
       required.  The  -s option can also be used to suppress the column head‐
       ings. The following  fields  always  produce  parsable  output:  ap_id,
       physid,  r_state,  o_state,  condition, busy  status_time_p, class, and
       type. Parsable output never has white-space characters embedded in  the
       field value.


       The  following  shell script fragment finds the first good unconfigured
       occupant of type CPU.



         found=
         cfgadm -l -s "noheadings,cols=ap_id:r_state:condition:type" | \
         while read ap_id r_state cond type
         do
              if [ "$r_state" = unconfigured -a "$cond" = ok -a "$type" = CPU ]
              then
                   if [ -z "$found" ]
                   then
                        found=$ap_id
                   fi
              fi
         done
         if [ -n "$found" ]
         then
                  echo "Found CPU $found"
         fi



       The format of the parsable time field  (status_time_p)  is  YYYYMMDDhh‐
       mmss,  giving  the  year, month, day, hour, minute and second in a form
       suitable for string comparison.


       Reference should be made to the  hardware  specific  documentation  for
       details of System Configuration Administration support.



Oracle Solaris 11.4               11 May 2021                        cfgadm(8)