sasinfo(8) 맨 페이지 - 윈디하나의 솔라나라

개요

섹션
맨 페이지 이름
검색(S)

sasinfo(8)

System Administration Commands                                      sasinfo(8)



NAME
       sasinfo - Serial Attached SCSI HBA port command line interface

SYNOPSIS
       sasinfo hba [-v] [HBA_Name]...


       sasinfo hba-port [-lvy] [-a HBA_Name] [HBA_port_nam]...


       sasinfo expander [-vt] [-p HBA_port_Name] [Expander_SAS_Addr]...


       sasinfo target-port [-s | -v] [Target_port_SAS_Addr]...


       sasinfo logical-unit | lu [-v] [device_path]...


       sasinfo [-V]


       sasinfo [-?]

DESCRIPTION
       The  sasinfo utility is a command line interface that collects adminis‐
       trative information on Serial Attached SCSI-2 (SAS-2) host bus  adapter
       (HBA)  that supports the Storage Management HBA API (SM-HBA). The util‐
       ity reports attributes of HBA ports and of expander  devices  and  SCSI
       target devices that might be connected to those HBA ports.


       sasinfo is implemented as a set of subcommands, described below.

SUB-COMMANDS
       The following subcommands are supported by sasinfo.

       hba

           Lists information for the HBA referenced by the specified HBA_name.
           If HBA_name is not specified, all HBAs on the host will be listed.


       hba-port

           Lists information for the HBA  port  referenced  by  the  specified
           HBA_port_Name.  If HBA_port_Name is not specified, all HBA ports on
           the host will be listed. Note that HBA  ports  can  be  dynamically
           configured/unconfigured  so  that the number of HBA ports on an HBA
           can change as connections to target devices are  established.  With
           no connections to a storage device, no HBA port is configured.


       expander

           Lists hierarchical view of the expander referenced by the specified
           Expander_SAS_Addr. If no argument is specified, all expanders  that
           are visible across all HBA ports on the host will be listed.


       target-port

           Lists  information  for  those  target  ports  referenced  by  Tar‐
           get_port_SAS_Addr address. If no argument is specified, all  target
           ports that are visible on the host will be listed.


       logical-unit | lu

           Lists  the logical unit referenced by the specified device_path. If
           device_path is not specified, all SAS logical units will be listed,
           including the SAS Management Protocol (SMP) target port.


OPTIONS
       The following options are supported.

       -?, --help

           Displays usage information


       -a, --hba HBA_Name

           Retrieve  HBA  port  information from the HBA_Name of an HBA on the
           host. The -a option can only be used with the hba-port subcommand.


       -l, --phy-linkstat

           Lists the link error statistics information for the phys on the HBA
           port  referenced by the specified HBA_port_Name or all HBA ports if
           no HBA port is specified. This option is used only  with  the  hba-
           port subcommand.


       -p HBA_port_SAS_Addr, --port HBA_port_SAS_Addr

           Retrieve  remote port information from the HBA_port_SAS_Addr of the
           local HBA port on the host. The -p option can be used only with the
           expander subcommand.


       -s, --scsi

           Lists  SCSI attributes for target ports that are requested for dis‐
           play. This option is only used for the target-port subcommand.


       -v, --verbose

           Display details on  hardware  information,  such  as  SAS  address,
           topology  device,  and  so  forth,  based  on  which  subcommand is
           invoked.


       -V, --version

           Displays the version information.


       -y, --phy

           Lists  the  phy  information  on  the   HBA   port   specified   by
           HBA_port_Name  or  all  HBA ports if no HBA port is specified. This
           option is used only with the hba-port subcommand.


EXAMPLES
       Example 1 Listing All HBAs



       The following command lists all HBAs on the host.


         # sasinfo hba
         HBA Name: SUNW-pmcs-0
         HBA Name: SUNW-pmcs-1


       Example 2 Listing All HBAs with Details



       The following command lists all HBAs on the host,  along  with  related
       details. Note that each HBA has two HBA ports configured, with each HBA
       port connected to a storage device.


         # sasinfo hba -v
         HBA Name: SUNW-pmcs-0
             Manufacturer: sun
             Model: SAS Gen-2
             Firmware Version: 1.1
             FCode/BIOS Version: 1.1
             Serial Number: 111-11111
             Driver Name: smvsl
             Driver Version: 1.1
             Number of HBA Ports: 2
         HBA Name: SUNW-pmcs-1
             Manufacturer: sun
             Model: SAS Gen-2
             Firmware Version: 1.1
             FCode/BIOS Version: 1.1
             Serial Number: 111-11111
             Driver Name: smvsl
             Driver Version: 1.1
             Number of HBA Ports: 2


       Example 3 Listing All HBA Ports



       The following command lists all HBA ports on the host.


         # sasinfo hba-port
         HBA Name: SUNW-pmcs-0
             HBA Port Name: /dev/cfg/c1
             HBA Port Name: /dev/cfg/c2
         HBA Name: SUNW-pmcs-1
             HBA Port Name: /dev/cfg/c3
             HBA Port Name: /dev/cfg/c4


       Example 4 Listing all HBA Ports with Details



       The following command lists all HBA ports, with accompanying details.


         # sasinfo hba-port -v
         HBA Name: SUNW-pmcs-0
             HBA Port Name: /dev/cfg/c1
                 Type: sas-device
                 State: online
                 Local SAS Address: 5000c50000d756aa
                 Attached Port SAS Address: 50800201a5a502bf
                 Number of Phys: 4
             HBA Port Name: /dev/cfg/c25000c50000d756cc
                 Type: sas-device
                 State: online
                 Local SAS Address: 5000c50000d756aa
                 Attached Port SAS Address: 50800201a5a503bf
                 Number of Phys: 4
         HBA Name: SUNW-pmcs-1
             HBA Port Name: /dev/cfg/c3
                 Type: sas-device
                 State: online
                 Local SAS Address: 5000c50000d756cc
                 Attached Port SAS Address: 50800201a5a504bf
                 Number of Phys: 4
             HBA Port Name: /dev/cfg/c4
                 Type: sas-device
                 State: online
                 Local SAS Address: 5000c50000d756cc
                 Attached Port SAS Address: 50800201a5a505bf
                 Number of Phys: 4


       Example 5 Listing phy Information for All HBA Ports



       The following command lists phy information for all HBA ports.


         # sasinfo hba-port -y
         HBA Name: SUNW-pmcs-0
             HBA Port Name: /dev/cfg/c1
                 Phy Information:
                  Identifier: 0
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 1
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 2
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 3
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
             HBA Port Name: /dev/cfg/c2
                 Phy Information:
                  Identifier: 4
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 5
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                 Identifier: 6
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                 Identifier: 7
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
         HBA Name: SUNW-pmcs-1
             HBA Port Name: /dev/cfg/c3
                 Phy Information:
                  Identifier: 0
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 1
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 2
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 3
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
             HBA Port Name: /dev/cfg/c4
                 Phy Information:
                  Identifier: 4
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 5
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 6
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit
                  Identifier: 7
                    State: enabled
                    HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                    ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                    NegotiatedLinkRate: 3Gbit


       Example 6 Listing phy Link Error Statistics for a Specific HBA Port



       The following command lists phy link error statistics for a  particular
       port.


         # sasinfo hba-port -ly /dev/cfg/c1
         HBA Name: SUNW-pmcs-0
           HBA Port Name: /dev/cfg/c1
             Phy Information:
               Identifier: 0
                State: enabled
                  HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                  ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                  NegotiatedLinkRate: 3Gbit
                  Link Error Statistics:
                    Invalid Dword: 0
                    Running Disparity Error: 0
                    Loss of Dword Sync: 0
                    Reset Problem: 0
               Identifier: 1
                  State: enabled
                  HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                  ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                  NegotiatedLinkRate: 3Gbit
                  Link Error Statistics:
                    Invalid Dword: 0
                    Running Disparity Error: 0
                    Loss of Dword Sync: 0
                    Reset Problem: 0
                Identifier: 2
                   State: enabled
                   HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                   ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                   NegotiatedLinkRate: 3Gbit
                   Link Error Statistics:
                     Invalid Dword: 0
                     Running Disparity Error: 0
                     Loss of Dword Sync: 0
                     Reset Problem: 0
                Identifier: 3
                   State: enabled
                   HardwareLinkRate(Min/Max): 1.5Gbit/3Gbit
                   ProgrammedLinkRate(Min/Max): 1.5Gbit/3Gbit
                   NegotiatedLinkRate: 3Gbit
                   Link Error Statistics:
                     Invalid Dword: 0
                     Running Disparity Error: 0
                     Loss of Dword Sync: 0
                     Reset Problem: 0


       Example 7 Listing Expanders Connected to an HBA Port



       The  following command lists all expanders that are visible through the
       specified HBA port.


         # sasinfo expander -p /dev/cfg/c1
         HBA Name: SUNW-pmcs-0
           HBA Port Name: /dev/cfg/c1
             Expander SAS Address(Tier 1): 50800201a5a502bf
                Expander SAS Address(Tier 2): 50800201a5a50233
                Expander SAS Address(Tier 2); 5000c5000d2da812
             Expander SAS Address(Tier 1): 50800201a5a503bf
                Expander SAS Address(Tier 2): 50800201a5a502d2
                Expander SAS Address(Tier 2); 5000c5000d2da823


       Example 8 Listing Detailed Information on Expanders



       The following command lists detailed information on all expanders  that
       are visible through the specified HBA port.


         # sasinfo expander -v -p /dev/cfg/c1
         HBA Name: SUNW-pmcs-0
           HBA Port Name: /dev/cfg/c1
             Expander SAS Address(Tier 1): 50800201a5a502bf
               OS Device Name: /dev/smp/expd0
               State: online
                 Expander SAS Address(Tier 2): 50800201a5a50233
                   OS Device Name: /dev/smp/expd2
                   State: online
                 Expander SAS Address(Tier 2); 5000c5000d2da812
                   OS Device Name: /dev/smp/expd3
                   State: online
             Expander SAS Address(Tier 1): 50800201a5a503bf
               OS Device Name: /dev/smp/expd1
               State: online
                 Expander SAS Address(Tier 2): 50800201a5a502d2
                   OS Device Name: /dev/smp/expd3
                   State: online
                 Expander SAS Address(Tier 2); 5000c5000d2da823
                   OS Device Name: /dev/smp/expd4
                   State: online


       Example 9 Listing Target Ports Attached to Expanders



       The  following  command  lists  all  target  ports that are attached to
       expanders connected to a specified HBA port.


         # sasinfo expander -t -p /dev/cfg/c1
         HBA Name: SUNW-pmcs-0
           HBA Port Name: /dev/cfg/c1
              Expander SAS Address(Tier 1): 50800201a5a502bf
                Target Port SAS Address: 50800201a5a504f1
                   Expander SAS Address(Tier 2): 50800201a5a50233
                     Target Port SAS Address: 50800201a5a502be
                     Target Port SAS Address: 5000c5000d2da8b2
                   Expander SAS Address(Tier 2); 5000c5000d2da812
                     Target Port SAS Address: 50800201a5a502be
                     Target Port SAS Address: 50800201a5a508b2
              Expander SAS Address(Tier 1): 50800201a5a503bf
                Target Port SAS Address: 50800201a5a50421
                   Expander SAS Address(Tier 2): 50800201a5a502d2
                     Target Port SAS Address: 50800201a5a503be
                     Target Port SAS Address: 5000c5000d2da7be
                   Expander SAS Address(Tier 2); 5000c5000d2da823
                     Target Port SAS Address: 50800201a5a503be
                     Target Port SAS Address: 5000c5000d2da7be


       Example 10 Listing Target Port Information



       The following command lists all target ports discovered on the host.


         # sasinfo target-port
         Target Port SAS Address: 5000c5000bae4009
         Target Port SAS Address: 5000c5000baef4b1
         Target Port SAS Address: 5000c5000bae3fe1
         Target Port SAS Address: 5000c5000bae49d9
         Target Port SAS Address: 5000c5000bae36c5


       Example 11 Listing Target Port Information with Topology Details



       The following command lists all target ports  with  the  HBA  port  and
       expander that they are connected to.


         # sasinfo target-port -v
         Target Port SAS Address: 5000c5000bae4009
           Type: SAS Device
           HBA Port Name: /dev/cfg/c7
             Expander Device SAS Address: 500e004aaaaaaa3f
           HBA Port Name: /dev/cfg/c5
             Expander Device SAS Address: 500e004aaaaaaa3f
         Target Port SAS Address: 5000c5000baef4b1
           Type: SAS Device
           HBA Port Name: /dev/cfg/c7
             Expander Device SAS Address: 500e004aaaaaaa3f
           HBA Port Name: /dev/cfg/c5
             Expander Device SAS Address: 500e004aaaaaaa3f
         Target Port SAS Address: 5000c5000bae3fe1
           Type: SAS Device
           HBA Port Name: /dev/cfg/c7
             Expander Device SAS Address: 500e004aaaaaaa3f
           HBA Port Name: /dev/cfg/c5
             Expander Device SAS Address: 500e004aaaaaaa3f
         Target Port SAS Address: 5000c5000bae49d9
           Type: SAS Device
           HBA Port Name: /dev/cfg/c7
             Expander Device SAS Address: 500e004aaaaaaa3f
           HBA Port Name: /dev/cfg/c5
             Expander Device SAS Address: 500e004aaaaaaa3f
         Target Port SAS Address: 5000c5000bae36c5
           Type: SAS Device
           HBA Port Name: /dev/cfg/c7
             Expander Device SAS Address: 500e004aaaaaaa3f
           HBA Port Name: /dev/cfg/c5
             Expander Device SAS Address: 500e004aaaaaaa3f


       Example 12 Listing Target Ports with SCSI Information



       The  following  command  lists  all target port details, including SCSI
       information for each target port.


         # sasinfo target-port -s 5000c5000bae4009
         Target Port SAS Address: 5000c5000bae4009
            Type: SAS Device
                 HBA Port Name: /dev/cfg/c7
                     Expander Device SAS Address: 500e004aaaaaaa3f
                         LUN : 0
                           OS Device Name : /dev/rdsk/c6t5000C5000BAE400Bd0s2
                           Vendor:   Sun
                           Product:  J4400
                           Device Type: Disk
                 HBA Port Name: /dev/cfg/c5
                     Expander Device SAS Address: 500e004aaaaaaa3f
                         LUN : 0
                           OS Device Name : /dev/rdsk/c6t5000C5000BAE400Bd0s2
                           Vendor:   Sun
                           Product:  J4400
                           Device Type: Disk


       Example 13 Listing the Logical Units



       The following command lists the logical units on a host.


         # sasinfo logical-unit
         OS Device Name: /dev/rdsk/c4t50020F2300B4904Ed0s2
         OS Device Name: /dev/rdsk/c4t50020F230000B4AFd0s2


       Example 14 Listing Additional Information on Logical Units



       The following command  displays  additional  logical  unit  information
       using the -v option for device /dev/rmt/On.


         # sasinfo lu -v
         OS Device Name: /dev/rdsk/c4t50020F2300B4904Ed0s2
            HBA Port Name: /dev/cfg/c1
              Target Port SAS Address: 50020f2300b4904e
                 LUN: 0
            Vendor: Sun
            Product: J4400
            Device Type: Disk
         OS Device Name: /dev/rdsk/c4t50020F230000B4AFd0s2
            HBA Port Name: /dev/cfg/c1
              Target Port SAS Address: 50020f230063100b
                 LUN: 0
            Vendor: Sun
            Product: J4400
            Device Type: Disk


ATTRIBUTES
       See attributes(7) for descriptions of the following attributes:


       tab()  box; cw(2.75i) |cw(2.75i) lw(2.75i) |lw(2.75i) ATTRIBUTE TYPEAT‐
       TRIBUTE VALUE _  Availabilitysystem/storage/sas-utilities  _  Interface
       StabilityCommitted


SEE ALSO
       attributes(7)



Oracle Solaris 11.4               16 Aug 2011                       sasinfo(8)