fmadm(8)
System Administration Commands fmadm(8)
NAME
fmadm - fault management configuration tool
SYNOPSIS
fmadm [-q] [subcommand [arguments]]
DESCRIPTION
The fmadm utility can be used by administrators and service personnel
to view and modify system configuration parameters maintained by the
Solaris Fault Manager, fmd(8). fmd receives symptomatic telemetry asso‐
ciated with conditions detected by the system software, diagnoses the
telemetry into faults, defects, or alerts, and initiates proactive
self-healing activities such as disabling faulty components.
fmadm can be used to do the following:
o View the set of diagnosis engines and agents that are cur‐
rently participating in fault management.
o View the list of system components that have been diagnosed
as associated with a fault, defect, or alert.
o Perform administrative tasks related to these entities.
The Fault Manager attempts to automate as many activities as possible,
so use of fmadm is typically not required. When the Fault Manager needs
help from an administrator, service repair technician, or Oracle, it
produces a message indicating its needs. It also refers you to a knowl‐
edge article on the Oracle website. The website might ask you to use
fmadm or one of the other fault management utilities to gather more
information or perform additional tasks. The documentation for fmd(8),
fmdump(8), and fmstat(8) man pages and the Securing Systems and
Attached Devices in Oracle Solaris 11.4 guide describe more about tools
to observe fault management activities.
One responsibility of the Fault Manager is to keep track of the loca‐
tion of components. At the chassis level, the fmadm *-alias subcommands
manage a chassis chassis-name.chassis-serial to alias-id mapping. The
administered alias-id is intended to describe the physical location of
a chassis.
The fmadm utility requires the user to be assigned the solaris.fm.read
RBAC authorization ("Fault Management" or "Fault Information" RBAC pro‐
file) for read operations, or the solaris.fm.modify RBAC authorization
("Fault Management" RBAC profile) for modify operations. The fmadm load
subcommand requires that the user possess all privileges.
SUBCOMMANDS
The fmadm command accepts the following subcommands. Some of the sub‐
commands accept or require additional options and operands. The acquit,
load, unload, repaired, replaced, reset, and rotate subcommands are
intended for trained technical personnel. Use of these subcommands
without the specific guidance of, for example, a Knowledge Base article
is not recommended.
fmadm acquit fmri | label [uuid]
Notify the Fault Manager that the specified resource is not to be
considered to be a suspect in the event identified by uuid, or if
no UUID is specified, then in any faults, defects, or alerts that
have been detected. The fmadm acquit command should be used only at
the direction of a documented Oracle repair procedure. Administra‐
tors might need to apply additional commands to re-enable a previ‐
ously faulted resource.
fmadm acquit uuid
Notify the Fault Manager that the event identified by uuid can be
safely ignored. The fmadm acquit command should be used only at the
direction of a documented Oracle repair procedure. Administrators
might need to apply additional commands to re-enable any previously
faulted resources.
fmadm add-alias chassis-name.chassis-serial alias-id ['comment']
The add-alias subcommand is used to establish alias-id as a managed
alias for the chassis-name.chassis-serial chassis. When a managed
alias is defined, the /dev/chassis devchassis(4FS) name space rep‐
resentation of the chassis will use the more meaningful alias-id
instead of the chassis-name.chassis-serial.
# fmadm add-alias SUN-Storage-J4410.1039QAQ007 RACK29.U25-28
The command shown above will verify that the new mapping does not
conflict with existing mappings. In the case of conflict, no map‐
ping change occurs. This command completes when the associated name
space updates are complete. If the updated name space does not use
the new alias-id, a warning is printed, but the mapping is updated.
If the name space update takes too long, a warning is printed.
The add-alias will now also accept "SYS" as an identifier for the
main chassis, instead of requiring the chassis-name.chassis-serial.
If an optional comment is provided, the comment is preserved and
will be displayed by a subsequent lookup-alias or list-alias com‐
mand. See also remove-alias and sync-alias.
fmadm clear label | uuid | class@resource
Notify the Fault Manager that any alert events associated with the
specified location label or uuid or identified by class@resource
should be cleared. This command can only be applied to an alert,
not to a defect or fault.
fmadm config
Display the configuration of the Fault Manager itself, including
the module name, version, and description of each component module.
Fault Manager modules provide services such as automated diagnosis,
self-healing, and messaging for hardware and software present on
the system.
fmadm faulty [-afprsv] [-u uuid]
This command is an alias for the fmadm list command.
fmadm flush fmri | label
Flush the information cached by the Fault Manager for the specified
resource, for any faults, defects, or alerts for which the resource
has already been repaired, acquitted or replaced.
fmadm list [-afprsv] [-u uuid]
Display status information for resources that the Fault Manager
currently believes to be associated with a fault, defect, or alert.
See also list-alert, list-defect, and list-fault subcommands.
The following options are supported:
-a Display all resources that might be associated with a
fault, defect, or alert. By default, the fmadm list com‐
mand only lists output for resources for which a fault,
defect, or alert is still active. If you specify the -a
option, all resource information cached by the Fault
Manager is listed, including information for resources
that might have already been acquitted or repaired, or
might no longer be present in the system.
-f Display FRUs (Field Replaceable Units) that are associ‐
ated with a fault, defect, or alert.
-p Pipe output through a pager with form feed between each
event.
-r Display affected Solaris resources with their Identifier
(FMRI) and their fault management state.
-s Display a one-line line summary for each event.
-u Only display the evueunitdwith the given uuid.
-v Display full output.
The percentage certainty is displayed if an event has multiple sus‐
pects, either of different classes or on different FRUs. If more
than one resource is on the same FRU and it is not 100% certain
that the event is associated with the FRU, the maximum percentage
certainty of the possible suspects on the FRU is displayed.
The Fault Manager associates the following states with every FRU
which that has been diagnosed as having a fault, defect, or alert.
faulty The FRU has been diagnosed by the Fault Man‐
ager as being associated with a fault,
defect, or alert, and is still present in the
system.
faulty/not_present The FRU has been diagnosed by the Fault Man‐
ager as being associated with a fault,
defect, or alert and is no longer present in
the system.
replaced The FRU has been removed from the system and
a replacement FRU has taken its place.
repaired The command fmadm repaired has been used to
notify the Fault Manager that the FRU has
been repaired.
acquitted The command fmadm acquit has been used to
notify the Fault Manager that the FRU has
been acquitted.
The state of any affected Solaris resources is also displayed. For
a faulty FRU, the state of the associated resources can be one of:
o Faulted and taken out of service
o Faulted but still in service
o Faulted but still providing degraded service
For a FRU that has been repaired, replaced or acquitted, the state
of the associated resources can be one of:
o Okay and in service
o Out of service, but associated components no longer
faulty
o Service degraded, but associated components no longer
faulty
fmadm list-alert [-afprsv] [-u uuid]
This subcommand behaves like list, but only displays suspect lists
that contain an alert event.
fmadm list-alias
The list-alias command is used to display all comments and map‐
pings. See also add-alias, lookup-alias, remove-alias, and sync-
alias subcommands.
fmadm list-defect [-afprsv] [-u uuid]
This subcommand behaves like list, but only displays suspect lists
that contain a defect event.
fmadm list-fault [-afprsv] [-u uuid]
This subcommand behaves like list, but only displays suspect lists
that contain a fault event.
fmadm load path
Load the specified Fault Manager module. The path must be an abso‐
lute path and must refer to a module present in one of the defined
directories for modules. Typically, the use of this command is not
necessary because the Fault Manager loads modules automatically
when Solaris initially boots or as needed. See also fmadm unload.
fmadm lookup-alias alias-id | chassis-name.chassis-serial
The lookup-alias subcommand can be used to determine what the cur‐
rent mapping is. The following is an example command.
# fmadm lookup-alias SUN-Storage-J4410.1039QAQ007
See also add-alias, list-alias, remove-alias, and sync-alias.
fmadm remove-alias alias-id | chassis-name.chassis-serial
The fmadm remove-alias subcommand is used to remove a chassis-
name.chassis-serial to alias-id mapping.
# fmadm remove-alias RACK29.U25-28
The command shown above completes when the associated name space
updates are complete. See also add-alias, list-alias, lookup-alias,
and sync-alias.
fmadm repaired fmri | label
Notify the Fault Manager that a repair procedure has been carried
out on the specified resource. The fmadm repaired command should be
used only at the direction of a documented Oracle repair procedure.
Administrators might need to apply additional commands to re-enable
a previously faulted resource.
fmadm replaced fmri | label
Notify the Fault Manager that the specified resource has been
replaced. This command should be used in those cases in which the
Fault Manager is unable to automatically detect the replacement.
The fmadm replaced command should be used only at the direction of
a documented Oracle repair procedure. Administrators might need to
apply additional commands to re-enable a previously faulted
resource.
fmadm reset [-s serd] module
Reset the specified Fault Manager module or module subcomponent. If
the -s option is present, the specified Soft Error Rate Discrimina‐
tion (SERD) engine is reset within the module. If the -s option is
not present, the entire module is reset and all persistent state
associated with the module is deleted. The fmadm reset command
should only be used at the direction of a documented Oracle repair
procedure. The use of this command is typically not necessary
because the Fault Manager manages its modules automatically.
fmadm rotate errlog | fltlog | infolog | infolog_hival
The fmadm rotate command is a helper command for the logadm(8) com‐
mand, so that logadm can rotate live log files correctly. The fmadm
rotate command is not intended to be invoked directly (and invoking
it directly is likely to lose log history). Use one of the follow‐
ing commands to cause the appropriate logfile to be rotated, if the
current logfile is not zero in size:
# logadm -p now -s 1b /var/fm/fmd/errlog
# logadm -p now -s 1b /var/fm/fmd/fltlog
# logadm -p now -s 1b /var/fm/fmd/infolog
# logadm -p now -s 1b /var/fm/fmd/infolog_hival
fmadm sync-alias
The sync-alias subcommand is used to hand-import a set of mappings
in bulk. Two copies of the current mappings are maintained:
o /etc/dev/chassis_aliases
o /etc/dev/.chassis_aliases
To import a set of mappings in bulk, you can update the
/etc/dev/chassis_aliases file and then run fmadm sync-alias. See
also add-alias, list-alias, lookup-alias, and remove-alias.
fmadm unload module
Unload the specified Fault Manager module. Specify module using the
basename listed in the fmadm config output. Typically, the use of
this command is not necessary because the Fault Manager loads and
unloads modules automatically based on the system configuration.
See also fmadm load.
OPTIONS
The following options are supported:
-q Set quiet mode. fmadm does not produce messages indicating the
result of successful operations to standard output.
OPERANDS
The following operands are supported:
subcommand The name of a subcommand listed in SUBCOMMANDS.
arguments One or more options or arguments appropriate for the
selected subcommand, as described in SUBCOMMANDS. Among
these arguments are fmri, uuid, and label. These identify
resources that are the objects of fmadm subcommands. Use
fmadm list to obtain the fmri, uuid, and label for a tar‐
geted resource. In general, label is the most user-
friendly of these operands. See the Examples section
below.
EXIT STATUS
The following exit values are returned:
0 Successful completion
1 An error occurred. Errors include a failure to communicate with
fmd or insufficient RBAC authorization to perform the requested
operation
2 Invalid command-line options were specified
EXAMPLES
Example 1 Invoking the list Subcommand
The following command invokes the list subcommand, which displays the
uuid, label, and fmri for a component.
# fmadm list
------------ ------------------------------------ ------------ ---------
TIME EVENT-ID MSG-ID SEVERITY
------------ ------------------------------------ ------------ ---------
Sep 09 16:15 96609fae-113c-e48c-b1cf-ebf4b0902d72 DISK-8000-3E Critical
Problem Status : open
Diag Engine : eft / 1.16
System
Manufacturer : Oracle-Corp.
Name : SUN-FIRE-X4170-SERVER
Part Number : unknown
Serial Number: 0920XF508B
----------------------------------------
Suspect 1 of 1:
Fault class: fault.io.scsi.cmd.disk.dev.rqs.derr
Certainty : 100%
Affects : dev:///:devid=id1,sd@n5000c5000940edbb//scsi_vhci/disk@g\
5000c5000940edbb
Status : faulted and taken out of service
FRU
Status : faulty
Location : "/SUN-Storage-J4410.1037QAQ052/HDD11"
Location Alias : "/RACK29.U25-28/HDD11"
Manufacturer : SEAGATE
Name : ST330057SSUN300G
Part Number : SEAGATE-ST330057SSUN300G
Revision : 0205
Serial Number : 000930G01CN4----3SJ01CN4
Chassis
Manufacturer : Oracle-Corp.
Name : SUN-Storage-J4410
Part Number : 594-5329
Serial Number : 1037QAQ052
...
...
In the preceding output, the uuid is the first item in the EVENT-ID
column, 96609fae-113c-e48c-b1cf-ebf4b0902d72. The label is in the FRU
section in the Location line, "/SUN-Storage-J4410.1037QAQ052/HDD11". In
this example, an alias for the chassis has been set, and the aliased
location is displayed in the Location Alias line,
"/RACK29.U25-28/HDD11".
The fmris are available with fmdump -v:
# fmdump -v
Sep 09 16:15:36.9252 96609fae-113c-e48c-b1cf-ebf4b0902d72 DISK-8000-3E \
Diagnosed 100% fault.io.scsi.cmd.disk.dev.rqs.derr
Problem in: hc://:scheme=:chassis-mfg=Oracle-Corp.:chassis-name=SUN-\
Storage-J4410:chassis-part=594-5329:chassis-serial=1037QAQ052/ses-\
enclosure=0/bay=11/disk=0
Affects: dev:///:devid=id1,sd@n5000c5000940edbb//\
scsi_vhci/disk@g5000c5000940edbb
FRU: hc://chassis-mfg=Oracle-Corp.:chassis-name=SUN-Storage-J4410\
:chassis-part=594-5329:chassis-serial=1037QAQ052:fru-mfg=SEAGATE\
:fru-name=SEAGATE-ST330057SSUN300G:fru-part=SEAGATE-ST330057SSUN300G\
:fru-revision=0205:fru-serial=000930G01CN4--------3SJ01CN4/\
ses-enclosure=0/bay=11/disk=0
FRU Location: "/SUN-Storage-J4410.1037QAQ052/HDD11"
Note that label is the easiest-to-use identifier. Either the aliased or
the non-aliased form of the Location may be used.
Example 2 Obtaining the Module Name
The following command displays the module name for each component. The
module name is specified as input to the fmadm unload command.
# fmadm config
MODULE VERSION STATUS DESCRIPTION
cpumem-retire 1.1 active CPU/Memory Retire Agent
disk-transport 1.0 active Disk Transport Agent
eft 1.16 active eft diagnosis engine
..
ATTRIBUTES
See attributes(7) for descriptions of the following attributes:
tab() box; cw(2.75i) |cw(2.75i) lw(2.75i) |lw(2.75i) ATTRIBUTE TYPEAT‐
TRIBUTE VALUE _ Availabilitysystem/fault-management _ Interface Stabil‐
itySee below
The command-line options are Committed. The human-readable output is
not-an-interface.
SEE ALSO
fmd(8), fmdump(8), fmstat(8), logadm(8), syslogd(8), attributes(7),
devchassis(4FS)
Securing Systems and Attached Devices in Oracle Solaris 11.4
NOTES
Oracle Solaris FMA does not determine or is not actively involved in
SMART failure analysis or predictions. It reads the SMART data reported
by the disk.
A third party utility such as SMARTCTL can be used to view more SMART
information, which is read-only. The thresholds are determined by the
disk manufacturer and can vary from one disk make/model/firmware level
to other. HDD manufacturers do not make SMART threshold information
available. However, SMARTCTL may be able to show you these values, but
it is read-only.
Once a disk asserts a SMART failure prediction or warning, it must be
replaced. You cannot turn off SMART failure prediction. Note that it is
a matter of time before the disk fails completely.
While it is possible to tell Oracle Solaris FMA to ignore a specific
SMART failure event by using the fmadm acquit command, it is not recom‐
mended. Again, once a disk asserts SMART failure, it cannot be changed
and must be replaced.
It is recommended to ensure that your system software and firmware
(including SAS controller and disk firmware) are all kept up to date.
This ensures the system has the best capabilities.
Oracle Solaris 11.4 11 May 2021 fmadm(8)