HPSA(4)                    Linux Programmer's Manual                   HPSA(4)

NAME
       hpsa - HP Smart Array SCSI driver

SYNOPSIS
       modprobe hpsa [ hpsa_allow_any=1 ]

DESCRIPTION
       hpsa is a SCSI driver for HP Smart Array RAID controllers.

   Options
       hpsa_allow_any=1:  This  option allows the driver to attempt to operate
       on any HP Smart Array hardware RAID controller, even if it is  not  ex‐
       plicitly  known to the driver.  This allows newer hardware to work with
       older drivers.  Typically this is used to allow installation of operat‐
       ing systems from media that predates the RAID controller, though it may
       also be used to enable hpsa to drive older controllers that would  nor‐
       mally  be  handled by the cciss(4) driver.  These older boards have not
       been tested and are not supported with hpsa, and cciss(4) should  still
       be used for these.

   Supported hardware
       The hpsa driver supports the following Smart Array boards:

           Smart Array P700M
           Smart Array P212
           Smart Array P410
           Smart Array P410i
           Smart Array P411
           Smart Array P812
           Smart Array P712m
           Smart Array P711m
           StorageWorks P1210m

       Since Linux 4.14, the following Smart Array boards are also supported:

           Smart Array 5300
           Smart Array 5312
           Smart Array 532
           Smart Array 5i
           Smart Array 6400
           Smart Array 6400 EM
           Smart Array 641
           Smart Array 642
           Smart Array 6i
           Smart Array E200
           Smart Array E200i
           Smart Array E200i
           Smart Array E200i
           Smart Array E200i
           Smart Array E500
           Smart Array P400
           Smart Array P400i
           Smart Array P600
           Smart Array P700m
           Smart Array P800

   Configuration details
       To configure HP Smart Array controllers, use the HP Array Configuration
       Utility  (either  hpacuxe(8)  or  hpacucli(8)) or the Offline ROM-based
       Configuration Utility (ORCA) run from the Smart Array's option  ROM  at
       boot time.

FILES
   Device nodes
       Logical drives are accessed via the SCSI disk driver (sd(4)), tape dri‐
       ves  via  the SCSI tape driver (st(4)), and the RAID controller via the
       SCSI  generic  driver  (sg(4)),  with  device  nodes  named   /dev/sd*,
       /dev/st*, and /dev/sg*, respectively.

   HPSA-specific host attribute files in /sys
       /sys/class/scsi_host/host*/rescan
              This  is a write-only attribute.  Writing to this attribute will
              cause the driver to scan for new, changed,  or  removed  devices
              (e.g.,  hot-plugged  tape drives, or newly configured or deleted
              logical drives, etc.)  and  notify  the  SCSI  midlayer  of  any
              changes  detected.  Normally a rescan is triggered automatically
              by HP's Array Configuration Utility (either the GUI or the  com‐
              mand-line  variety);  thus,  for logical drive changes, the user
              should not normally have to use this attribute.  This  attribute
              may be useful when hot plugging devices like tape drives, or en‐
              tire storage boxes containing preconfigured logical drives.

       /sys/class/scsi_host/host*/firmware_revision
              This attribute contains the firmware version of the Smart Array.

              For example:

                  # cd /sys/class/scsi_host/host4
                  # cat firmware_revision
                  7.14

   HPSA-specific disk attribute files in /sys
       /sys/class/scsi_disk/c:b:t:l/device/unique_id
              This  attribute contains a 32 hex-digit unique ID for each logi‐
              cal drive.

              For example:

                  # cd /sys/class/scsi_disk/4:0:0:0/device
                  # cat unique_id
                  600508B1001044395355323037570F77

       /sys/class/scsi_disk/c:b:t:l/device/raid_level
              This attribute contains the RAID level of each logical drive.

              For example:

                  # cd /sys/class/scsi_disk/4:0:0:0/device
                  # cat raid_level
                  RAID 0

       /sys/class/scsi_disk/c:b:t:l/device/lunid
              This attribute contains the 16 hex-digit  (8  byte)  LUN  ID  by
              which  a  logical  drive  or  physical  device can be addressed.
              c:b:t:l are the controller, bus, target, and lun of the device.

       For example:

                  # cd /sys/class/scsi_disk/4:0:0:0/device
                  # cat lunid
                  0x0000004000000000

   Supported ioctl() operations
       For compatibility with applications written for  the  cciss(4)  driver,
       many,  but  not  all of the ioctls supported by the cciss(4) driver are
       also supported by the hpsa driver.  The data structures used  by  these
       ioctls   are   described   in   the   Linux   kernel  source  file  in‐
       clude/linux/cciss_ioctl.h.

       CCISS_DEREGDISK, CCISS_REGNEWDISK, CCISS_REGNEWD
              These three ioctls all do exactly the same thing,  which  is  to
              cause  the  driver to rescan for new devices.  This does exactly
              the same thing as writing to the hpsa-specific host "rescan" at‐
              tribute.

       CCISS_GETPCIINFO
              Returns PCI domain, bus, device and function and "board ID" (PCI
              subsystem ID).

       CCISS_GETDRIVVER
              Returns driver version in three bytes encoded as:

                  (major_version << 16) | (minor_version << 8) |
                      (subminor_version)

       CCISS_PASSTHRU, CCISS_BIG_PASSTHRU
              Allows "BMIC" and "CISS" commands to be passed  through  to  the
              Smart Array.  These are used extensively by the HP Array Config‐
              uration   Utility,   SNMP   storage  agents,  and  so  on.   See
              cciss_vol_status at ⟨http://cciss.sf.net⟩ for some examples.

SEE ALSO
       cciss(4), sd(4), st(4), cciss_vol_status(8), hpacucli(8), hpacuxe(8),

       ⟨http://cciss.sf.net⟩, and Documentation/scsi/hpsa.txt  and  Documenta‐
       tion/ABI/testing/sysfs-bus-pci-devices-cciss in the Linux kernel source
       tree

COLOPHON
       This  page  is  part of release 5.02 of the Linux man-pages project.  A
       description of the project, information about reporting bugs,  and  the
       latest     version     of     this    page,    can    be    found    at
       https://www.kernel.org/doc/man-pages/.

Linux                             2017-09-15                           HPSA(4)
맨 페이지 내용의 저작권은 맨 페이지 작성자에게 있습니다.
RSS ATOM XHTML 5 CSS3