cfgadm(8)               System Administration Commands               cfgadm(8)

NAME
       cfgadm - configuration administration

SYNOPSIS
       /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_options]
            -c function ap_id...


       /usr/sbin/cfgadm [-f] [-y | -n] [-v] [-o hardware_options]
            -x hardware_function ap_id...


       /usr/sbin/cfgadm [-v] [-a] [-s listing_options]
            [-o hardware_options] [-l [ap_id | ap_type]]


       /usr/sbin/cfgadm [-v] [-o hardware_options] -t ap_id...


       /usr/sbin/cfgadm [-v] [-o hardware_options] -h
            [ap_id | ap_type]

DESCRIPTION
       The  cfgadm command provides configuration administration operations on
       dynamically reconfigurable hardware resources. These operations include
       displaying status, (-l), initiating testing, (-t), invoking  configura‐
       tion  state  changes, (-c), invoking hardware specific functions, (-x),
       and obtaining configuration administration help messages (-h). Configu‐
       ration administration is performed  at  attachment  points,  which  are
       places  where system software supports dynamic reconfiguration of hard‐
       ware resources during continued operation of Solaris.


       Configuration administration makes a distinction between  hardware  re‐
       sources  that  are  physically  present in the machine and hardware re‐
       sources that are configured and visible to Solaris. The nature of  con‐
       figuration administration functions are hardware specific, and are per‐
       formed by calling hardware specific libraries.


       Configuration  administration operates on an attachment point. Hardware
       resources located at attachment points can or can not be physically re‐
       placeable during system operation, but are  dynamically  reconfigurable
       by way of the configuration administration interfaces.


       An  attachment  point  defines  two unique elements, which are distinct
       from the hardware resources that exist beyond the attachment point. The
       two elements of an attachment point are a receptacle and  an  occupant.
       Physical  insertion  or removal of hardware resources occurs at attach‐
       ment points and results in a receptacle gaining or losing an  occupant.
       Configuration  administration  supports  the physical insertion and re‐
       moval operations as well as other  configuration  administration  func‐
       tions at an attachment point.


       Attachment  points have associated state and condition information. The
       configuration administration interfaces provide control for transition‐
       ing attachment point states. A receptacle can exist  in  one  of  three
       states:  empty,  disconnected or connected, while an occupant can exist
       in one of two states: configured or unconfigured.


       A receptacle can provide the empty state, which is the normal state  of
       a  receptacle  when the attachment point has no occupants. A receptacle
       can also provide the disconnected state if it  has  the  capability  of
       isolating its occupants from normal system access. Typically this state
       is used for various hardware specific testing prior to bringing the oc‐
       cupant's resources into full use by the system, or as a step in prepar‐
       ing  an  occupant for physical removal or reconfiguration. A receptacle
       in the disconnected state isolates its occupant from the system as much
       as its hardware allows, but can provide access for testing and setup. A
       receptacle must provide the connected state, which allows normal access
       to hardware resources contained on any occupants. The  connected  state
       is  the normal state of a receptacle that contains an occupant and that
       is not currently undergoing configuration administration operations.


       The hardware resources contained on an  occupant  in  the  unconfigured
       state  are  not  represented  by normal Solaris data structures and are
       thus not available for use by Solaris. Operations allowed on an  uncon‐
       figured  occupant  are  limited  to configuration administration opera‐
       tions. The hardware resources of an occupant in  the  configured  state
       are  represented by normal Solaris data structures and thus some or all
       of those hardware resources can be in use  by  Solaris.  All  occupants
       provide both the configured and unconfigured states,


       An  attachment  point  can  be  in one of five conditions: unknown, ok,
       failing, failed, or unusable. An attachment point can enter the  system
       in  any  condition  depending  upon  results of power-on tests and non-
       volatile record keeping.


       An attachment point with an occupant in the configured state is in  one
       of  four  conditions: unknown, ok, failing, or failed. If the condition
       is not failing or failed an attachment point can change to failing dur‐
       ing the course of operation if a hardware dependent  recoverable  error
       threshold  is  exceeded.  If  the condition is not failed an attachment
       point can change to failed during operation as a result of an  unrecov‐
       erable error.


       An  attachment  point with an occupant in the unconfigured state can be
       in any of the defined conditions. The condition of an attachment  point
       with  an unconfigured occupant can decay from ok to unknown after a ma‐
       chine dependent time threshold. Initiating a test function changes  the
       attachment  point's condition to ok, failing or failed depending on the
       outcome of the test. An attachment point that does not provide  a  test
       function  can leave the attachment point in the unknown condition. If a
       test is interrupted, the attachment point's condition can be set to the
       previous condition, unknown or failed. An attachment point in  the  un‐
       known, ok, failing, or failed conditions can be re-tested.


       An  attachment  point can exist in the unusable condition for a variety
       of reasons, such as inadequate power or cooling for the receptacle,  an
       occupant  that  is unidentifiable, unsupported, incorrectly configured,
       etc. An attachment point in the unusable condition can never be used by
       the system. It typically remains in this condition until  the  physical
       cause is remedied.


       An attachment point also maintains busy information that indicates when
       a state change is in progress or the condition is being reevaluated.


       Attachment  points  are referred to using hardware specific identifiers
       (ap_ids) that are related to the type and location  of  the  attachment
       points  in  the system device hierarchy. An ap_id can not be ambiguous,
       it must identify a single attachment point. Two types of ap_id specifi‐
       cations are supported: physical and logical. A physical ap_id  contains
       a  fully specified pathname, while a logical ap_id contains a shorthand
       notation that identifies an attachment point in  a  more  user-friendly
       way.


       For example, an attachment point representing a system's backplane slot
       number  7  could  have  a  physical ap_id of /devices/central/fhc/sysc‐
       trl:slot7 while the logical ap_id could be system:slot7. Another  exam‐
       ple,  the  third receptacle on the second PCI I/O bus on a system could
       have a logical ap_id of pci2:plug3.


       Attachment points may also be created dynamically. A dynamic attachment
       point is named relative to a base attachment point which is present  in
       the system. ap_ids for dynamic attachment points consist of a base com‐
       ponent  followed  by  two colons (::) and a dynamic component. The base
       component is the base attachment point ap_id. The dynamic component  is
       hardware  specific and generated by the corresponding hardware specific
       library.


       An ap_type is a partial form of a logical ap_id that can  be  ambiguous
       and  not  specify  a  particular attachment point. An ap_type is a sub‐
       string of the portion of the logical ap_id up to but not including  the
       colon  (:) separator. For example, an ap_type of pci would show all at‐
       tachment points whose logical ap_ids begin with pci.


       The use of ap_types is discouraged. The new select sub-option to the -s
       option provides a more general and flexible mechanism for selecting at‐
       tachment points. See OPTIONS.


       The cfgadm command interacts primarily with  hardware  dependent  func‐
       tions contained in hardware specific libraries and thus its behavior is
       hardware dependent.


       For  each configuration administration operation a service interruption
       can be required. Should the completion of the  function  requested  re‐
       quire  a noticeable service interruption to interactive users, a prompt
       is output on the standard error output for confirmation on the standard
       input before the function is started. Confirmation  can  be  overridden
       using  the  -y  or  -n options to always answer yes or no respectively.
       Hardware specific options, such as test level, are supplied as  sub-op‐
       tions using the -o option.


       Operations  that  change  the state of the system configuration are au‐
       dited by the system log daemon syslogd(8).


       The arguments for this command conform to the  getopt(3C)  and  getsub‐
       opt(3C) syntax convention.

OPTIONS
       The following options are supported:

       -a

           Specifies  that  the  -l  option  must also list dynamic attachment
           points.


       -cfunction

           Performs the state change function on the attachment  point  speci‐
           fied by ap_id.

           Specify  function as insert, remove, disconnect, connect, configure
           or unconfigure. These functions cause state transitions at the  at‐
           tachment  point  by  calling hardware specific library routines and
           are defined in the following list.


           insert         Performs operations that allows the user to manually
                          insert an occupant or to activate  a  hardware  sup‐
                          plied  mechanism  that  performs the physical inser‐
                          tion. insert can have hardware specific side effects
                          that temporarily suspend activity in portions of the
                          system. In such cases the hardware specific  library
                          generates  appropriate  warning messages and informs
                          the user of any special considerations or procedures
                          unique to that hardware. Various  hardware  specific
                          errors  can  cause this function to fail and set the
                          receptacle condition to unusable.


           remove         Performs operations that allow the user to  manually
                          remove  an  occupant  or to activate a hardware sup‐
                          plied mechanism to perform the physical removal. re‐
                          move can have hardware specific  side  effects  that
                          temporarily suspend activity in portions of the sys‐
                          tem.  In  such  cases  the hardware specific library
                          generates appropriate warning messages  and  informs
                          the user of any special considerations or procedures
                          unique  to  that hardware. Various hardware specific
                          errors can cause this function to fail and  set  the
                          receptacle condition to unusable.


           disconnect     Performs  hardware  specific operations to put a re‐
                          ceptacle in the disconnected state, which  can  pre‐
                          vent  an occupant from operating in a normal fashion
                          through the receptacle.


           connect        Performs hardware specific operations to put the re‐
                          ceptacle in the connected state, which allows an oc‐
                          cupant to operate in a normal  fashion  through  the
                          receptacle.


           configure      Performs  hardware specific operations that allow an
                          occupant's hardware resources to be  usable  by  So‐
                          laris. Occupants that are configured are part of the
                          system configuration and are available for manipula‐
                          tion by Solaris device manipulation maintenance com‐
                          mands (eg: psradm(8), mount(8), ifconfig(8)).


           unconfigure    Performs hardware specific operations that logically
                          remove  an  occupant's  hardware  resources from the
                          system. The occupant must  currently  be  configured
                          and its hardware resources must not be in use by So‐
                          laris.

           State transition functions can fail due to the condition of the at‐
           tachment  point  or  other  hardware  dependent considerations. All
           state change functions in the direction of adding  resources,  (in‐
           sert, connect, and configure) are passed onto the hardware specific
           library  when  the  attachment point is in the ok or unknown condi‐
           tion. All other conditions require the use of the force  option  to
           allow  these functions to be passed on to the hardware specific li‐
           brary. Attachment point condition does not prevent a hardware  spe‐
           cific library being called for related to the removal (remove, dis‐
           connect,  and  unconfigure)  of hardware resources from the system.
           Hardware specific libraries can reject state  change  functions  if
           the attachment point is in the unknown condition.

           The  condition of an attachment point is not necessarily changed by
           the state change functions, however errors during state change  op‐
           erations  can  change the attachment point condition. An attempt to
           override a condition and force a state change that would  otherwise
           fail can be made by specifying the force option (-f). Hardware spe‐
           cific safety and integrity checks can prevent the force option from
           having any effect.


       -f

           Forces the specified action to occur. Typically, this is a hardware
           dependent  override of a safety feature. Forcing a state change op‐
           eration can allow use of the hardware resources of occupant that is
           not in the ok or unknown conditions, at the discretion of any hard‐
           ware dependent safety checks.


       -h [ap_id | ap_type ... ]

           Prints out the help message text. If ap_id or ap_type is specified,
           the help routine of the hardware specific library for  the  attach‐
           ment point indicated by the argument is called.


       -l [ap_id | ap_type ... ]

           Lists  the  state and condition of attachment points specified. At‐
           tachment points can be filtered by using the -s option  and  select
           sub-option.  Invoking  cfgadm  without one of the action options is
           equivalent to -l without an argument. The format of the  list  dis‐
           play  is controlled by the -v and -s options. When the -a option is
           specified attachment points are dynamically expanded.


       -n

           Suppress any interactive confirmation and assume that the answer is
           no. If neither -n or -y is specified, interactive  confirmation  is
           obtained  through the standard error output and the standard input.
           If either of these standard channels does not correspond to a  ter‐
           minal (as determined by isatty(3C)) then the -n option is assumed.


       -ohardware_options

           Supplies  hardware specific options to the main command option. The
           format and content of the  hardware  option  string  is  completely
           hardware  specific.  The option string hardware_options conforms to
           the getsubopt(3C) syntax convention.


       -slisting_options

           Supplies listing options to the list (-l) command.  listing_options
           conforms  to  the  getsubopt(3C) syntax convention. The sub-options
           are used to specify the attachment point  selection  criteria  (se‐
           lect=select_string),     the     type     of    matching    desired
           (match=match_type), order of listing  (sort=field_spec),  the  data
           that  is displayed (cols=field_spec and cols2=field_spec), the col‐
           umn delimiter (delim=string) and whether to suppress  column  head‐
           ings (noheadings).

           When  the  select  sub-option  is specified, only attachment points
           which match the specified criteria will be listed. The select  sub-
           option has the following syntax:




             cfgadm -s select=attr1(value1):attr2(value2)...

           where  an  attr is one of ap_id, class or type. ap_id refers to the
           logical ap_id field, class refers to  attachment  point  class  and
           type  refers to the type field. value1, value2, etc. are the corre‐
           sponding values to be matched. The type of match can  be  specified
           by the match sub-option as follows:




             cfgadm -s match=match_type,select=attr1(value1)...


           where  match_type can be either exact or partial. The default value
           is exact.

           Arguments to the select sub-option can be quoted  to  protect  them
           from the shell.

           A  field_spec  is  one or more data-fields concatenated using colon
           (:), as in data-field:data-field:data-field. A data-field is one of
           ap_id,  physid,  r_state,  o_state,  condition,  type,  busy,  sta‐
           tus_time, status_time_p, class, and info. The ap_id field output is
           the  logical  name for the attachment point, while the physid field
           contains the physical name. The r_state field can be empty, discon‐
           nected or connected. The o_state field can be configured or  uncon‐
           figured.  The busy field can be either y if the attachment point is
           busy, or n if it is not. The type and info fields are hardware spe‐
           cific. The status_time field provides the time at which either  the
           r_state,  o_state,  or  condition  of  the  attachment  point  last
           changed. The status_time_p field is a parsable version of the  sta‐
           tus_time field. If an attachment point has an associated class, the
           class  field  lists the class name. If an attachment point does not
           have an associated class, the class field lists none.

           The order of the fields in field_spec is significant: For the  sort
           sub-option,  the first field given is the primary sort key. For the
           cols and cols2 sub-options, the fields are printed in the order re‐
           quested. The order of sorting on a data-field can  be  reversed  by
           placing a minus (−) before the data-field name within the field_sec
           for  the  sort sub-option. The default value for sort is ap_id. The
           defaults values for cols and cols2 depend on whether the -v  option
           is  given:  Without  it cols is ap_id:r_state:o_state:condition and
           cols2 is not set. With  -v   cols  is  ap_id:r_state:o_state:condi‐
           tion:info  and  cols2 is status_time:type:busy:physid:. The default
           value for delim is a single space. The value  of  delim  can  be  a
           string  of arbitrary length. The delimiter cannot include comma (,)
           character, see getsubopt(3C). These listing options can be used  to
           create parsable output. See NOTES.


       -t

           Performs a test of one or more attachment points. The test function
           is used to re-evaluate the condition of the attachment point. With‐
           out  a  test  level specifier in hardware_options, the fastest test
           that identifies hard faults is used.

           More comprehensive tests are hardware specific and are selected us‐
           ing the hardware_options.

           The results of the test is used to  update  the  condition  of  the
           specified  occupant to either ok if no faults are found, failing if
           recoverable faults are found or failed if any unrecoverable  faults
           are found.

           If  a  test is interrupted, the attachment point's condition can be
           restored to its previous value or set to unknown if no errors  were
           found or failing if only recoverable errors were found or to failed
           if any unrecoverable errors were found. The attachment point should
           only be set to ok upon normal completion of testing with no errors.


       -v

           Executes  in  verbose mode. For the -c, -t and -x options outputs a
           message giving the results of each attempted operation. Outputs de‐
           tailed help information for the -h option. Outputs verbose informa‐
           tion for each attachment point for the -l option.


       -xhardware_function

           Performs hardware specific  functions.  Private  hardware  specific
           functions can change the state of a receptacle or occupant. Attach‐
           ment  point  conditions  can change as the result of errors encoun‐
           tered during private hardware specific functions.  The  format  and
           content of the hardware_function string is completely hardware spe‐
           cific.  The option string hardware_function conforms to the getsub‐
           opt(3C) syntax convention.


       -y

           Suppresses any interactive confirmation and assume that the  answer
           is yes.


USAGE
       The  required  privileges  to  use this command are hardware dependent.
       Typically, a default system configuration restricts all  but  the  list
       option to the superuser.

EXAMPLES
       Example 1 Listing Attachment Points in the Device Tree



       The  following  example  lists all attachment points except dynamic at‐
       tachment points.




         example# cfgadm

           Ap_Id         Type        Receptacle      Occupant       Cond
         system:slot0    cpu/mem     connected       configured     ok
         system:slot1    sbus-upa    connected       configured     ok
         system:slot2    cpu/mem     connected       configured     ok
         system:slot3    unknown     connected       unconfigured   unknown
         system:slot4    dual-sbus   connected       configured     failing
         system:slot5    cpu/mem     connected       configured     ok
         system:slot6    unknown     disconnected    unconfigured   unusable
         system:slot7    unknown     empty           unconfigured   ok
         c0              scsi-bus    connected       configured     unknown
         c1              scsi-bus    connected       configured     unknown




       Example 2 Listing All Configurable Hardware Information



       The following example lists all current configurable hardware  informa‐
       tion, including those represented by dynamic attachment points:




         example# cfgadm -al

           Ap_Id            Type         Receptacle      Occupant        Cond
         system:slot0       cpu/mem      connected       configured      ok
         system:slot1       sbus-upa     connected       configured      ok
         system:slot2       cpu/mem      connected       configured      ok
         system:slot3       unknown      connected       unconfigured    unknown
         system:slot4       dual-sbus    connected       configured      failing
         system:slot5       cpu/mem      connected       configured      ok
         system:slot6       unknown      disconnected    unconfigured    unusable
         system:slot7       unknown      empty           unconfigured    ok
         c0                 scsi-bus     connected       configured      unknown
         c0::dsk/c0t14d0    disk         connected       configured      unknown
         c0::dsk/c0t11d0    disk         connected       configured      unknown
         c0::dsk/c0t8d0     disk         connected       configured      unknown
         c0::rmt/0          tape         connected       configured      unknown
         c1                 scsi-bus     connected       configured      unknown




       Example 3 Listing Selectively, Based on Attachment Point Attributes



       The  following  example  lists all attachment points whose class begins
       with scsi, ap_id begins with c and type field begins with scsi. The ar‐
       gument to the -s option is quoted to protect it from the shell.




         example# cfgadm -s "match=partial,select=class(scsi):ap_id(c):type(scsi)"

         Ap_Id         Type          Receptacle      Occupant           Cond
          c0          scsi-bus      connected       configured         unknown
          c1          scsi-bus      connected       configured         unknown




       Example 4 Listing Current Configurable Hardware Information in  Verbose
       Mode



       The  following  example lists current configurable hardware information
       for ap-type  system in verbose mode:




         example# cfgadm -v -l system
         Ap_Id                      Receptacle Occupant   Condition Information
         When         Type      Busy     Phys_Id
         system:slot1               connected  configured ok
         Apr  4 23:50 sbus-upa  n        /devices/central/fhc/sysctrl:slot1
         system:slot3               connected  configured ok        non-detachable
         Apr 17 11:20 cpu/mem   n        /devices/central/fhc/sysctrl:slot3
         system:slot5               connected  configured ok
         Apr  4 23:50 cpu/mem   n        /devices/central/fhc/sysctrl:slot5
         system:slot7               connected  configured ok
         Apr  4 23:50 dual-sbus n        /devices/central/fhc/sysctrl:slot7





       The When column represents the status_time field.

       Example 5 Testing Two Occupants Using the  Hardware  Specific  Extended
       Test



       The  following  example tests two occupants using the hardware specific
       extended test:




         example# cfgadm -v -o extended -t system:slot3 system:slot5
         Testing attachment point system:slot3 ...  ok
         Testing attachment point system:slot5 ...  ok


       Example 6 Configuring an Occupant Using the Force Option



       The following example configures an occupant in the  failing  state  to
       the system using the force option:




         example# cfgadm -f -c configure system:slot3


       Example 7 Unconfiguring an Occupant From the System



       The following example unconfigures an occupant from the system:




         example# cfgadm -c unconfigure system:slot4


       Example 8 Configuring an Occupant at an Attachment Point



       The following example configures an occupant:




         example# cfgadm -c configure c0::dsk/c0t0d0


ENVIRONMENT VARIABLES
       See  environ(7) for descriptions of the following environment variables
       that affect the execution of cfgadm: LC_TIME, LC_MESSAGES, NLSPATH  and
       TZ.

       LC_MESSAGES    Determines how cfgadm displays column headings and error
                      messages.  Listing  output  data  is not affected by the
                      setting of this variable.


       LC_TIME        Determines how cfgadm  displays  human  readable  status
                      changed time (status_time).


       TZ             Specifies  the time zone used when converting the status
                      changed time. This applies to both  the  human  readable
                      (status_time) and parsable (status_time_p) formats.


EXIT STATUS
       The following exit values are returned:

       0    Successful completion.


       1    An error occurred.


       2    Configuration administration not supported on specified target.


       3    Usage error.


ATTRIBUTES
       See attributes(7) for descriptions of the following attributes:

       tab()  box; cw(2.75i) |cw(2.75i) lw(2.75i) |lw(2.75i) ATTRIBUTE TYPEAT‐
       TRIBUTE VALUE _ Availabilitysystem/dynamic-reconfiguration


SEE ALSO
       config_admin(3CFGADM), getopt(3C), getsubopt(3C),  isatty(3C),  attrib‐
       utes(7),  environ(7),  cfgadm_fp(8),  cfgadm_ib(8),  cfgadm_pci(8), cf‐
       gadm_sata(8),  cfgadm_sbd(8),  cfgadm_scsi(8),  cfgadm_usb(8),   ifcon‐
       fig(8), mount(8), prtdiag(8), psradm(8), syslogd(8)

DIAGNOSTICS
       Diagnostic messages appear on the standard error output. Other than op‐
       tions  and usage errors, the following are diagnostic messages produced
       by this utility:

         cfgadm: Configuration administration not supported on ap_id


         cfgadm: No library found for ap_id


         cfgadm: ap_id is ambiguous


         cfgadm: operation: Insufficient privileges


         cfgadm: Attachment point is busy, try again


         cfgadm: No attachment points with specified attributes found


         cfgadm: System is busy, try again


         cfgadm: operation: Operation requires a service interruption



         cfgadm: operation: Data error: error_text


         cfgadm: operation: Hardware specific failure: error_text



       See config_admin(3CFGADM) for additional details regarding  error  mes‐
       sages.

NOTES
       Hardware  resources  enter the unconfigured pool in a hardware specific
       manner. This can occur at various times such as: system  initialization
       or  as a result of an unconfigure operation. An occupant that is in the
       unconfigured state is not available for use by the  system  until  spe‐
       cific  intervention  occurs.  This intervention can be manifested as an
       operator initiated command or it can be by way of an automatic  config‐
       uring mechanism.


       The  listing  option  of  the  cfgadm  command  can  be used to provide
       parsable input for another command, for example within a shell  script.
       For  parsable  output,  the -s option must be used to select the fields
       required. The -s option can also be used to suppress the  column  head‐
       ings.  The  following  fields  always  produce  parsable output: ap_id,
       physid, r_state, o_state, condition, busy   status_time_p,  class,  and
       type.  Parsable output never has white-space characters embedded in the
       field value.


       The following shell script fragment finds the first  good  unconfigured
       occupant of type CPU.



         found=
         cfgadm -l -s "noheadings,cols=ap_id:r_state:condition:type" | \
         while read ap_id r_state cond type
         do
              if [ "$r_state" = unconfigured -a "$cond" = ok -a "$type" = CPU ]
              then
                   if [ -z "$found" ]
                   then
                        found=$ap_id
                   fi
              fi
         done
         if [ -n "$found" ]
         then
                  echo "Found CPU $found"
         fi



       The  format  of  the parsable time field (status_time_p) is YYYYMMDDhh‐
       mmss, giving the year, month, day, hour, minute and second  in  a  form
       suitable for string comparison.


       Reference should be made to the hardware specific documentation for de‐
       tails of System Configuration Administration support.